Note on use¶
The following restrictions apply with the delivery of the Industrial Edge DataXess Configurator.
System Requirement¶
- Memory: 130 MB (This is required to install the app on an IED)
- Storage: 352.17 MB
Limitations with DataXess¶
-
Maximum of 5 devices can be added in a group including aggregator device.
-
One device can be a part of only one group.
Sample test results¶
Following table provides the test results performed with 4 Acquisition device and 1 Aggregator device. For the testing, only 1 topic is configured per Acquisition device and only 1 topic is published to Aggregator device.
For every 100ms the data from the 4 Acquisition device’s is published to 1 Aggregator device.
| Aspects | Acquisition | Aggregator |
|---|---|---|
| Number of device | 4 (maximum) | 1 |
| Number of Publishers | 1 topic per device | NA |
| Number of Subscribers | NA | 1 topic per device |
| Number of Topics | 1/publisher | 4/subscriber |
| Quality of Service (QoS) | 1 | 1 |
| Message publishing rate | 100ms | |
| Throughput (Messages/Second/topic) | 10 | 9.91 |
| Message size | 512 KB/message | ~2MB |